Uploaded image for project: 'JDK'
  1. JDK
  2. JDK-8217744

[TESTBUG] JFR TestShutdownEvent fails on some systems due to process surviving SIGINT

    Details

    • Subcomponent:
      jfr
    • Resolved In Build:
      b06

      Backports

        Description

        This issue was reported by Goetz; it is specific to some SAP systems. I was unable to reproduce it in Oracle test system so far.

        Test case (sub-test) that fails: TestSig
            Log states: "Running subtest 7 (jdk.jfr.event.runtime.TestShutdownEvent$TestSig)"

        Error message:
        =========================
        Exception in thread "main" java.lang.RuntimeException: Process survived the SIGINT signal!
        at jdk.test.lib.Asserts.fail(Asserts.java:594)
        at jdk.jfr.event.runtime.TestShutdownEvent$TestSig.runTest(TestShutdownEvent.java:230)
        at jdk.jfr.event.runtime.TestShutdownEvent$TestMain.main(TestShutdownEvent.java:111)

        Exit code: 1
        Error: Value not equal to Shutdown requested from Java, field='reason', value='No remaining non-daemon Java threads': expected No remaining non-daemon Java threads to equal Shutdown requested from Java
        =========================

        Proposed solution:
           Instead of asserting when the process survived SIGINT (or other signal), the test case should be more flexible/robust and skip the rest of the test case, continue to the rest of the test.